Screen Image
|

|
Explanation
|
If any of the twistlocks are sensed to be between the fully open or fully closed positions then the Sidelifter arms will be disabled.
|
Causes
|
- Twistlocks not moved to fully open or fully closed
- Faulty twistlock sensor switch
- Faulty twistlock sensor switch wiring
|
Operator Actions
|
- Enter Top Lift Frame mode and open or close the twistlocks fully
- Use override code to continue operation
- Request service
|
Service Tasks
|
- Go to VIEW SENSOR VALUES, VIEW SPECIAL OPTIONS, TOP LIFT FRAME, TWISTLOCKS. Each twistlock states is displayed. Activate the twistlocks and check that the twistlock states change accordingly
- Check the twistlock switches are operating correctly by removing the inspection covers on top of frame corner giving the problem
|