Previous Topic

Next Topic

Book Contents

Book Index

Send Feedback

Load On Lifting Pin – Stabilisers Cannot Be Deployed F37 R38

Screen Image

 

37 = FRONT CRANE

38 = REAR CRANE

Explanation

Stabiliser mode has been entered while there is still load on the lifting pin (G-Pin).

Causes

  • The load has not been fully released from the arms
  • The top arm pressure sensor is faulty

Operator Actions

  • Check that the load has been released from the arms and retry stabiliser mode.
  • Use override code to continue operation
  • Request service

Service Tasks

  • Check the top arm pressure sensor value by going to VIEW SENSOR VALUES then FRONT or REAR ANGLE SENSORS. At the bottom of the page the pressure in the top arm cylinder will be displayed. With no load on the G-Pin the pressure should be less than 20bar
  • If the reading is more than 20bar regardless of any loading on the G-Pin then replace the pressure sensor
  • When replacing the sensor make sure that the top arm is fully folded down and that all hydraulic pressure in the cylinder is released by using the manual lever on the Danfoss PVG valve. Wear eye protection.

See Also

LCD Error or Warning Screens

Module Angle Sensor Error F78 R79

Stabiliser Angle Sensor Error F25 R26

Bottom Arm Angle Sensor Error F19 R20

Top Arm Pressure Sensor Error F21 R23

Top Arm Angle Sensor Error F11 R18

Stabiliser Down Sensor Error F16 R15

Communication With Front Crane Lost! 60

Communication With Rear Crane Lost ! 61

Low Control System Voltage 62

Road Camber Beyond Safe Working Limit 12

Road Camber Beyond Safe Working Limit 13

Road Elevation Beyond Safe Working Limit 22

Road Elevation Beyond Safe Working Limit 24

Warning Angle Sensors Not Calibrated F53 R113

Stability Warning F29 R32

Stability Alarm F27 F30

Offside Stability Alarm F28 R31

Stabiliser Not Deployed – Arm Function Disabled F33 R34

Module Off Station – Stabilisers Cannot Be Deployed F39 R40

Stabiliser Deployed – Traverse Function Disabled F45 R44

Stabiliser not angled enough F69 R70

Ankle not extended enough F71 R72

Ankle Retract Sensor Error F104 R105

Ankle Extend Sensor Error F106 R107

Joystick Error Reported L65 R66

No Joystick Data Received 64

Mode Select Switch Error 75

ECU communication lost with Radio Receiver F96 R97

Front Crane Has Lost Communication with Engine ECU 95

Diesel Engine Oil Pressure too low 100

Diesel Engine Water Temperature too High 99

Alternator Not Charging 109

Trailer Park Brake Not Applied 110

Top Lift Frame - Twistlock Switch Error FR120 FL121 RR 122 RR 123

Top Lift Frame - Contact Sensor Error FR124 FL125 RR126 RL127

Top Lift Frame – Twistlocks Are In-between Open and Closed 128

Top Lift Frame Is Not Fitted 129

Max Rated Load Exceeded 58

Stabiliser Extension Magnetic Counter Sensor F130 R131

Angle Sensor Calibration Failure