Screen Image
19 = FRONT CRANE
20 = REAR CRANE
|

|
Explanation
|
Fault detected between Crane Junction Box and Bottom Arm Angle Sensor
The Bottom Arm Angle Sensor measures the angle of the bottom arm.
|
Causes
|
- Damaged sensor cable or connector plug
- Moisture in sensor connecting plug
- Faulty sensor
|
Operator Actions
|
- Check connector plug firmly seated and not damaged
- Use override code to continue operation
- Request service
|
Service Tasks
|
- Check sensor cable and connector plug.
- Replace the sensor. The orientation of the sensor is important and the cable should point upwards. Recalibrate using procedure SL0005.
- Check the calibration by hanging a plumb bob from the D-Pin and position the bottom arm in the vertical position so that the D-Pin is vertical to the A-Pin.
- With the diesel engine not running but SMARTlift switched on, go to Manufacturers Area View Pin Distances-View Front or Rear Pin Distances-View Horizontal Distance AD. The distance should be zero +/- 10mm.
- Remember, all angle sensors are the same component so it is possible to swap sensors in order to help diagnose faulty wiring or a faulty sensor. Just remember to recalibrate any sensor that is moved!
|