Screen Image
78 = FRONT CRANE
79 = REAR CRANE
|

|
Explanation
|
Fault detected between Crane Junction Box and a module angle sensor
The module angle sensor measures the elevation and camber of the trailer.
|
Causes
|
- Damaged sensor cable or connector plug
- Moisture in sensor connecting plug
- Faulty sensor
|
Operator Actions
|
- Check connector plug firmly seated and not damaged
- Use override code to continue operation
- Request service
|
Service Tasks
|
- Check sensor cable and connector plug.
- Replace the sensor. The orientation of the sensor is important and the cable should point upwards. Recalibrate using procedure SL0005.
- With the trailer parked on level ground the elevation should be 0° and the camber should be 0°. These values can be seen at View Sensor Values
- Remember, all angle sensors are the same component so it is possible to swap sensors in order to help diagnose faulty wiring or a faulty sensor. Just remember to recalibrate any sensor that is moved!
|