The battery charger is connected permanently to the main battery and is available for use even when the Sidelifter start key is turned to the OFF position.
Figure 2
When the battery is inserted into the charger, the charge LED flashes. The charge process is terminated it detects peak battery voltage, or after 5 hours, after which the ready LED glows. While the ready LED is glowing, the charger continues to trickle charge the battery. The battery cannot be damaged by leaving it in the charger. Fast charge is less than 2 hours.
If the battery is bad and has an open cell, no LEDs will light up. If the battery has a shorted cell, the charge LED will blink continuously. In either case, do not use the battery. Properly dispose of a bad battery.
|