H0018 print PDF |
Version 2 |
Hydraulics |
07 Aug 03 |
||
The 90% switch activates an amber warning lamp. The 100% switch activates a red warning lamp and an audible beeper. |
Refer to Sidelifter Technical Bulletin TB0028 for information on switch models.
Step |
Action |
1. |
Locate the Danfoss PVG main relief valve. Refer Service Info H0005. Use the relief valve to reduce the main system pressure to 90% of the maximum operating pressure. |
2. |
Adjust the 90% switch to enable the amber lamp to illuminate at this pressure. |
3. |
Reset the main relief to the system to the correct max operating pressure. |
4. |
Adjust the 100% switch to enable the 100% lamp and audible beeper at this pressure. |
5. |
Replace the rubber plug. |