TB0064 Camber and Elevation Change in SMARTlift settings

24 Jan 2008 PDF File

Author: Richard Brown

 

 

Camber and Elevation limits were changed from Sidelifter SB7850 onwards. Units prior to SB7850 that have had a software upgrade to 3.22 or above will also be affected. (Go to MAIN MENU - VIEW OPERATING HOURS - The software version is in the top right hand corner.)

This information is also in the Operators Manual provided with all units.

Camber Limit

Prior to SB7850 = +/- 10deg

After SB7850 = +/-6deg

Elevation Limit

Prior to SB7850 = +/- 6deg

After SB7850 = +/-4deg

Impact of change

If the camber/elevation limits are exceeded, a warning screen will display. The current value will display at any time in the Sensor Values Menu.