SL0018 Fixing Corrupt Memory Sectors

SL0018 PDF File

Version 1

SMARTlift

13 Sept 07

This procedure applies to the following errors:

It is normal for these errors to appear the first time an ECU is started. The reason for this is because the memory is empty and the computer interprets this as an error. In order to get rid of the error messages, the memory must be filled with data.

To do this:

Memory Sector 1 Fix for Front and Rear crane.

Memory Sector 2 Fix for Front and Rear crane.

To fix this, use the calibration procedure for the front and rear cranes.

(shortcut to get rid of error message

– go to: Menu/Manufacturers Area/Calibrate Angle Sensors/Calibrate All)

Be careful about performing a "Calibrate ALL". If you don't have an error message for "Memory Sector #2 Corrupt", then DO NOT do this because you will lose all the work you did to calibrate each arm (you should only use "Calibrate Individual" setting).

Memory Sector 3 Fix for Front and Rear crane.

To fix this go to Menu/Crane Synchronisation, and enter the pin number 1112

Go into Top Arm crane synchronisation and change by 1 the value for: