E0009 SB360/SB300/SB330 Diode Safety Retrofit System

9 Dec 2003 PDF File

Version 2

Electrics

 

Refer to:

  1. Drill the holes as per drawing S6-33170 or S3-33171
  2. Extend the sensor cable if required using small solder sleeves (RS 157-2972)
  3. Install the Proximity Sensor in the barrel housing (without 90° elbow or gland) Using the SICK sensor testing device and 2mm sensing distance setting tool (EL-33172), set the proximity sensor extension. Apply Loctite 222 and install the locknut. Install the 90° elbow and gland. Install the M5 SHCS.
  4. Check that the tip of the proximity sensor is not protruding beyond the stabiliser housing. (the sensor has a 4mm range, so it should be 2mm recessed)
  5. Install the conduit
  6. Install the additional contact blocks into module junction boxes, install block/relay assembly into main control cabinet
  7. Test the system logic

System Logic

Warning Buzzer And Light

New Hella Relay (no)

New 4 Pole Relay (no)

Top Arm Up

Top Arm Down

Bottom Arm Up

Bottom Arm Down

Both Stabilisers Touching The Ground

No

Open

Closed (diodes Bypassed)

Yes

Yes

Yes

Yes

Either Or Both Stabilisers Off The Ground

Yes

Closed

Open (diodes Active)

No

Yes

Yes

No